Photometer 8000

Photometer 8000

The Palintest Photometer 8000 sets a new standard for water quality testing and ease of operation. It is designed to provide accurate and fast analysis for even the busiest test labs. Covering the full range of tests for clean and wastewater, it is compatible with all Palintest tablet and liquid photometer tests.

With no moving parts, all measurements are made instantly, providing a very fast sample throughput. Compatible Palintest Tubetests reagent tubes are coded to provide all the instrument needs for wavelength range and calibration set-up and analysis. The instrument recognizes the tube method and measurement range and automatically sets up for a measurement. The user simply pushes in the tube and the instrument does the rest!

The unique multi-size cell holder adjusts automatically to all reagent tubes from 12mm to 20mm diameter with no inserts or adaptors required, again speeding up analysis, and making the unit very convenient for the routine analysis of large numbers of samples since no manual intervention is required to change ranges or tube sizes. The cell holder is fully jam- and trap-resistant to allow fast and secure tube swapping.

With an innovative permanent dual light source, the correct wavelength is automatically selected. A high efficiency light-focusing system provides a very high level of light throughput to the cells. The high intensity sources are up to 10 times brighter than the conventional optics found in other instruments and the optical system eliminates stray light effects, allowing the instrument to be used at maximum precision.

Dynamic Active Light Level Compensation in the optical system eliminates drift and ensures accurate measurements immediately from switch on, with no warm-up period required, providing a fast and convenient sample throughput.

The unique light lensing system with reference channels optimizes precision by compensating for optical imperfections in reagent tubes.

The Photometer 8000 is fully software driven, with a large backlit touch-screen providing easy access to all instrument functions. The software includes a rapid self-test of the complete instrument including the innovative optical system. The diagnostics continue to run in permanent monitoring mode to check power supply, light levels and system integrity, reporting to the user immediately any variation that would affect the analysis

Ordering Information

Click here to order reagents

DescriptionProduct Code
Photometer 8000 KitReagents not included.PT800Buy online
Photometer 8000 Optional Carrying CasePT803Buy online
Round Test Tubes for Photometer, 10 ml glass (Pack of 5)PT595/5Buy online
Photometer 8000 Check Standards with Test CertificatePT802Buy online
Printer Ink Ribbon CartridgePT263Buy online
Complete Photometer Instruction BookZIPHOTBuy online

Press Releases

New Economical Heater Block for COD Testing

New Economical Heater Block for COD Testing

September 2005

Water analysis specialist Palintest has introduced a new, high capability, multi-tube heater block. The block is ideal for chemical oxygen demand (COD) reactions and enables Palintest to offer economical COD test kits for use with its Tubetest® system. These include heater block, test tube rack, photometer adaptor and micropipettor.

Read more

Palintest Helps Watch Over Angel's Fish

Palintest Helps Watch Over Angel's Fish

May 2005

When the owners of the new Angel of the North Fishing Lakes and Wildlife Sanctuary required fast, accurate water testing they turned to Palintest. The company?s new easy-to-use Photometer 8000 provides instant results on all the major inorganic constituents of water together with additives and pollutants. It enables a fast response to issues affecting fish welfare, providing peace of mind for the management.

Read more

Keeping Photometers at Their Peak - Palintest at Your Service

Keeping Photometers at Their Peak - Palintest at Your Service

December 2003

To ensure that Palintest photometers provide continual peak performance and are maintained at the highest possible specification, the company no offers customers a complete range of service options and upgrades. In addition, Palintest offers trade-in deals on older photometers, and trade-ups to other instruments in the current range including the company?s brand new Photometer 8000.

Read more

COD Test conforms to International standard

COD Test conforms to International standard

October 2003

The Palintest Tubetest® system offers a simple, quick, and convenient method of testing chemical oxygen demand (COD) which conforms to the new ISO standard on sealed-tube COD testing (BS ISO 15705:2002).

Read more

Advanced Specification Photometer

Advanced Specification Photometer

May 2003

Water analysis specialist Palintest has introduced a new photometer, the Photometer 8000, which delivers rapid, accurate results and is easy to use. It offers advanced performance with a fully featured specification, has user calibration capability, and can analyse all the major inorganic constituents of water together with treatment additives and pollutants.

Read more